Correlation between magnetic resonance enterography and ileo-colonoscopy for assessment of disease activity in terminal ileal Crohn's disease.
Publication/Presentation Date
10-1-2022
Abstract
BACKGROUND: Magnetic resonance enterography (MRE) has emerged as a novel tool for the assessment of disease activity in Crohn's disease (CD). Real world data from Indian subcontinent on performance of MRE in terminal ileal CD are lacking.
METHODS: Retrospective analysis of patients with terminal ileal CD who underwent both ileo-colonoscopy and MRE was performed. Ileo-colonoscopy was considered the gold standard for assessment of disease activity. On ileo-colonoscopy, a simple endoscopic score for Crohn's disease (SES-CD) ≥2 was considered active disease; presence of ulcers indicated severe disease. MRE scoring of the disease activity was performed using magnetic resonance index of activity (MARIA) and simplified MARIA (MARIAs). The measure of agreement between ileo-colonoscopy and MRE and comparison of MARIA and MARIAs for assessment of disease activity and sensitivity of MRE to detect mucosal ulcerations were calculated.
RESULTS: Seventy patients with terminal ileal CD (mean age 40.74±15.56 years; 71.4% males [n=50]) were evaluated. The sensitivities of MARIA and MARIAs scores to detect active disease were 0.76 and 0.84, respectively. The area under the receiver operating characteristic curve (AUROC) for detecting severe disease was 0.836 (p< 0.0001) for MARIA and 0.861 (p< 0.0001) for MARIAs. For mild active disease, there was no agreement between SES-CD and MARIA or MARIAs; however, for severe disease, the agreement was fair and moderate for MARIA and MARIAs, respectively. MARIA and MARIAs were comparable for identification of active and severe disease (κ 0.759, p< 0.0001 and κ 0.840, p< 0.0001, respectively). MRE was 68.18% sensitive to detect mucosal ulcers.
CONCLUSION: MRE is a reliable and sensitive tool for detection of endoscopically severe, but not mild, terminal ileal CD.
Volume
41
Issue
5
First Page
465
Last Page
474
ISSN
0975-0711
Published In/Presented At
Kakkar, C., Singh, A., Mahajan, R., Midha, V., Goyal, S., Narang, V., Gupta, K., Singh, D., Bansal, N., Saggar, K., & Sood, A. (2022). Correlation between magnetic resonance enterography and ileo-colonoscopy for assessment of disease activity in terminal ileal Crohn's disease. Indian journal of gastroenterology : official journal of the Indian Society of Gastroenterology, 41(5), 465–474. https://doi.org/10.1007/s12664-022-01242-7
Disciplines
Medicine and Health Sciences
PubMedID
36357600
Department(s)
Fellows and Residents
Document Type
Article