Diverse Use of the WEB Device: A Technical Note on WEB Stenting and WEB Coiling of Complex Aneurysms.

Publication/Presentation Date

10-1-2019

Abstract

The Woven EndoBridge (WEB) device, an intrasaccular flow-diverter that does not require long-term antiplatelet use, has recently emerged as an alternative to embolize complex intracranial aneurysms; however, there are limitations to the WEB device. First, it does not immediately secure the aneurysm in most subarachnoid hemorrhage cases. Second, it may not be suitable for embolization of wide-neck aneurysms with an unfavorable aspect ratio. To overcome these limitations, we have used the WEB device in conjunction with stenting and/or coiling. Here, we present a technical note with an illustrated case series and provide a detailed step-by-step description on how the WEB device can be used in adjunct to coiling and/or stenting to achieve successful angiographic results. Accurate sizing of the WEB device before deployment is critical. Larger case series are required to further assess the safety and success of these combined techniques.

Volume

130

First Page

201

Last Page

205

ISSN

1878-8769

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

31301439