Total hip arthroplasty for acute femoral neck fractures using a cementless tapered femoral stem.

Publication/Presentation Date

12-1-2006

Abstract

The purpose of this study was to evaluate the osseointegration potential and implant-related complications of cementless total hip arthroplasty with a titanium alloy collarless, tapered, wedge-shaped femoral stem with a proximal circumferential plasma-spray coating in patients with acute hip fractures. The cohort consists of 85 patients with a mean age of 78.1 years. The mean duration of follow-up was 3.8 years. Total hip arthroplasty conferred significant improvement in function for all patients. All femoral components were stable with evidence of bone ingrowth (84 hips) or fibrous fixation (1 hip). Mild thigh pain was present in 3 patients. The complications included dislocation (3 cases), intraoperative femoral fracture (2 cases), and periprosthetic femoral fracture in the postoperative period (1 case). There was one reoperation for revision of the femoral component in the patient with a periprosthetic fracture. There were 25 (29%) deaths. Cementless total hip arthroplasty using a tapered proximally coated femoral stem is a viable option for the treatment of a displaced hip fracture and preexistent arthritis.

Volume

21

Issue

8

First Page

1134

Last Page

1140

ISSN

0883-5403

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

17162172