Temporary mechanical circulatory support after orthotopic heart transplantation: a single-centre experience.

Publication/Presentation Date

7-1-2017

Abstract

OBJECTIVES: There are various strategies in the use of temporary mechanical circulatory support following orthotopic heart transplant (OHT). We sought to examine the outcomes following different temporary mechanical circulatory support strategies for acute graft failure.

METHODS: Patients who received an OHT between 2001 and 2015 at a single institution were retrospectively reviewed. Patients were divided into 2 groups based on the need for temporary mechanical circulatory support (TMCS).

RESULTS: A total of 9.9% (19 of 192) of patients required TMCS following OHT. There were no significant differences in the preoperative demographics between groups. Six patients (32%) required a biventricular assist device, 9 patients (47%) required a right ventricular assist device and 4 patients (21%) required a veno-arterial extracorporeal membrane oxygenator. Perioperative morbidity was comparable between all groups. Our entire TMCS cohort had 94.7% 30-day and 61.1% 1-year survival. When compared with the OHT patients with no TMCS (97.1% at 30 days and 92.8% at 1 year), survival was inferior in TMCS patients ( P  = 0.01 at 30 days, P  <  0.001 at 1 year, P  <  0.001 overall).

CONCLUSIONS: Acute graft failure requiring TMCS has inferior overall survival. Larger, multi-institutional studies are needed to further elucidate these differences and identify the best TMCS mode.

Volume

25

Issue

1

First Page

41

Last Page

46

ISSN

1569-9285

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

28387838

Department(s)

Administration and Leadership

Document Type

Article

Share