Outcomes of EUS-guided drainage of debris-containing pancreatic pseudocysts by using combined endoprosthesis and a nasocystic drain.

Publication/Presentation Date

10-1-2013

Abstract

BACKGROUND: The presence of debris within a pseudocyst may impair success of endoscopic drainage.

OBJECTIVE: To compare the clinical outcomes and adverse-event rates of EUS-guided pseudocyst drainage with and without a nasocystic drain for the management of pancreatic pseudocysts with viscous solid debris-laden fluid.

DESIGN: Retrospective study.

SETTING: Single, tertiary-care referral center.

PATIENTS: Consecutive patients with pancreatic pseudocysts managed by EUS-guided drainage: those with solid debris who underwent drainage via nasocystic drains alongside stents (n = 63) and those with solid debris who underwent drainage via transmural stents only (n = 24).

INTERVENTION: Drainage via nasocystic drains alongside stents or drainage via transmural stents only.

MAIN OUTCOME MEASUREMENTS: The primary outcomes were short-term success and long-term success of the procedures. The secondary outcomes were procedure-related adverse events and reintervention.

RESULTS: The patients with viscous solid debris-laden fluid whose pseudocysts were drained by both stents and nasocystic tubes had a 3 times greater short-term success rate compared with those who had drainage by stents alone (P = .03). On 12-month follow-up, complete resolution of pseudocysts with debris drained via stents alone was less (58%) compared with those with debris who underwent drainage via nasocystic drains alongside stents (79%; P = .059). The rate of stent occlusion was higher in cysts with debris drained by stents alone (33%) compared with those drained via nasocystic drains alongside stents (13%; P = .03).

LIMITATIONS: Retrospective design; limited sample size.

CONCLUSION: In patients with pseudocysts with viscous debris-laden fluid, EUS-guided drainage by using a combination of a nasocystic drain and transmural stents improves clinical outcomes and lowers the stent occlusion rate compared with those who underwent drainage via stents alone.

Volume

78

Issue

4

First Page

589

Last Page

595

ISSN

1097-6779

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

23660566

Department(s)

Administration and Leadership

Document Type

Article

Share

COinS