Surgical Outcomes Following Fixation of Peri-Implant Distal Radius Fractures: A Case Series.

Publication/Presentation Date

2-1-2022

Abstract

PURPOSE: The purpose of this study was to evaluate surgical outcomes following fixation of peri-implant distal radius fractures.

METHODS: A retrospective chart review was conducted of peri-implant distal radius fractures treated surgically at a large academic practice over 18 years. Patients were included if they had previously undergone open reduction and internal fixation of a distal radius fracture; subsequently sustained a fracture at, or adjacent to, the existing hardware; and then undergone revision fixation with the removal of hardware. Fractures were categorized into 3 groups: type A (distal to the implant), type B (at the level of the implant), and type C (proximal to the implant). Outcomes, including range of motion, Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire scores, and radiographic alignment, were recorded at the latest follow-up visit.

RESULTS: Twelve peri-implant distal radius fractures that had undergone revision surgical fixation were identified. At the time of injury, the average patient age was 63 years. Ten occurred around a volar plate, 1 occurred around an intramedullary device, and 1 occurred around a dorsal plate. One fracture occurred proximal to previous hardware (type C), 9 fractures occurred at the level of previous hardware (type B), and 2 fractures occurred distal to previous hardware (type A). The median time from initial fixation to peri-implant fracture was 2.7 years. At a mean follow-up of 6 months after the removal of the hardware and revision fixation, radiographic alignment was within acceptable parameters for all injuries. At the final follow-up, the average wrist motion for flexion, extension, supination, and pronation were 66°, 66°, 83°, and 86°, respectively. The average DASH score was 6.7. Three patients experienced complications.

CONCLUSIONS: Although peri-implant fractures are infrequent complications following distal radius fracture internal fixation, outcomes of surgically treated peri-implant distal radius fractures are satisfactory with respect to radiographic alignment, range of motion, and function.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Volume

47

Issue

2

First Page

1

Last Page

192

ISSN

1531-6564

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

34119367

Department(s)

Administration and Leadership

Document Type

Article

Share

COinS