PURPOSE: Intra-operative (real-time) treatment planning has been adapted by many institutions for low-dose rate prostate brachytherapy. Although this allows dosimetric planning to be done during the procedure, preplan imaging to obtain a prostate volume is essential to identify the number of seeds to ensure adequate volume coverage. Currently, there is no consensus regarding the most appropriate imaging to obtain this information. We conducted a retrospective study to compare how volumes obtained from preplan CT (p-CT) scans or preplan transrectal ultrasound (p-TRUS) correlated with real-time ultrasound and postimplant CT volumes and the difference in accuracy of seed estimation between these techniques.
METHODS AND MATERIALS: Ninety-two patients underwent (125)I permanent seed implants at Thomas Jefferson University Hospital between February 2002 and August 2008. Fifty-one patients underwent p-TRUS before intra-operative planning and 41 patients were evaluated by p-CT.
RESULTS: The median difference in volume between preimplant imaging and the intra-operative planning ultrasound was 3.59 and 5.2cc for patients who underwent p-TRUS and p-CT, respectively. p-TRUS volumes more closely correlated with real-time intra-operative volumes (R=0.84 in all patients and R=0.91 in hormone-naïve patients) vs. p-CT (R=0.82). The median number of seeds wasted using p-CT was 18 vs. 7 using volumes derived from p-TRUS.
CONCLUSIONS: The number of seeds ordered could be more accurately obtained from p-TRUS volumes, and this translated into less seed wastage. Our findings indicate that p-TRUS is a more accurate and an economically superior alternative to p-CT imaging in the era of real-time ultrasound planning.
Volume
9
Issue
4
First Page
335
Last Page
340
ISSN
1873-1449
Published In/Presented At
Fogh, S., Doyle, L., Yu, A., Li, J., Weiner, P., Suh, D., Comber, E., Dicker, A. P., Yu, Y., Xiao, Y., & Harrison, A. (2010). A comparison of preplan transrectal ultrasound with preplan-CT in assessing volume and number of seeds needed for real-time ultrasound-based intra-operative planning in prostate (125)I seed implantation. Brachytherapy, 9(4), 335–340. https://doi.org/10.1016/j.brachy.2009.09.005
Disciplines
Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods
PubMedID
20226742
Department(s)
Administration and Leadership
Document Type
Article