Closure of a Prosthetic Mitral Valve Paravalvular Leak Using a Ventricular Septal Defect (VSD) Amplatzer Occluder Device.
Publication/Presentation Date
1-30-2021
Abstract
BACKGROUND Paravalvular leaks (PVL) are becoming more commonly experienced in clinical practice due to the increasing number of mitral valve replacements performed. There are about 182 000 valve replacements performed annually, with a 5-15% prevalence rate of paravalvular leaks. Due to increased mortality associated with surgical repair, percutaneous transcatheter closure procedures are increasingly being performed as an alternative to repeat surgery. CASE REPORT We present the case of a 52-year-old woman with past medical history of mitral valve endocarditis who developed worsening acute heart failure 1 month after surgical bioprosthetic mitral valve replacement. Transesophageal echocardiography at the time revealed dehiscence of the bioprosthetic mitral valve and severe mitral regurgitation. She subsequently had emergent surgical bioprosthetic mitral valve replacement and annular reconstruction. The post-operative course was complicated by increasing dyspnea and lower-extremity edema, with recurrent pericardial tamponade requiring placement of a pericardial window. Based on her multiple comorbidities, most notably the concomitant right ventricular failure with severe pulmonary hypertension and prior pericardial patch repair with compromise of her mitral valve annulus, she was deemed inoperable for re-do surgery and eventually underwent a successful percutaneous closure of the mitral paravalvular leak with a ventricular septal defect (VSD) Amplatzer occluder device. The patient made good recovery and was discharged home a few days after the procedure. CONCLUSIONS Although use of the Amplatzer VSD occluder device for this indication currently remains off-label, our report supports the use of the VSD occluder device in this subset of patients considering the high mortality rates associated with repeat surgical procedure.
Volume
22
First Page
928003
Last Page
928003
ISSN
1941-5923
Published In/Presented At
Oladiran, O., Areoye, G., Oladunjoye, A. O., Oladunjoye, O. O., Elgin, E., & Licata, A. (2021). Closure of a Prosthetic Mitral Valve Paravalvular Leak Using a Ventricular Septal Defect (VSD) Amplatzer Occluder Device. The American journal of case reports, 22, e928003. https://doi.org/10.12659/AJCR.928003
Disciplines
Medicine and Health Sciences
PubMedID
33514683
Department(s)
Department of Medicine, Cardiology Division
Document Type
Article