Robotic-Assisted Percutaneous Coronary Intervention of a Saphenous Vein Graft Stenosis using a FilterWire EZ Embolic Protection.

Publication/Presentation Date

2-1-2018

Abstract

Robotic-assisted coronary angioplasty has been utilized to decrease radiation exposure to cardiologists, and to diminish risk of orthopedic and ergonomic injuries caused by wearing heavy lead during long procedures. The efficacy and safety of robotic-assisted percutaneous coronary intervention for relatively low-risk lesions was demonstrated in the PRECISE study. Successful percutaneous coronary interventions using robotic system for treatment of complex high-risk lesions have been reported in few case series so far. We describe a successful robotic-assisted coronary angioplasty for a complex lesion of saphenous vein graft using a FilterWire EZ embolic protection. This case illustrates the feasibility to use robotic-assisted angioplasty for complex cases.

Volume

71

Issue

2

First Page

59

Last Page

61

ISSN

0038-3317

Disciplines

Medicine and Health Sciences

PubMedID

29990411

Department(s)

Department of Medicine, Cardiology Division

Document Type

Article

Share

COinS