Robotic-Assisted Percutaneous Coronary Intervention of a Saphenous Vein Graft Stenosis using a FilterWire EZ Embolic Protection.
Publication/Presentation Date
2-1-2018
Abstract
Robotic-assisted coronary angioplasty has been utilized to decrease radiation exposure to cardiologists, and to diminish risk of orthopedic and ergonomic injuries caused by wearing heavy lead during long procedures. The efficacy and safety of robotic-assisted percutaneous coronary intervention for relatively low-risk lesions was demonstrated in the PRECISE study. Successful percutaneous coronary interventions using robotic system for treatment of complex high-risk lesions have been reported in few case series so far. We describe a successful robotic-assisted coronary angioplasty for a complex lesion of saphenous vein graft using a FilterWire EZ embolic protection. This case illustrates the feasibility to use robotic-assisted angioplasty for complex cases.
Volume
71
Issue
2
First Page
59
Last Page
61
ISSN
0038-3317
Published In/Presented At
Anuwatworn, A., Stys, T., & Stys, A. (2018). Robotic-Assisted Percutaneous Coronary Intervention of a Saphenous Vein Graft Stenosis using a FilterWire EZ Embolic Protection. South Dakota medicine : the journal of the South Dakota State Medical Association, 71(2), 59–61.
Disciplines
Medicine and Health Sciences
PubMedID
29990411
Department(s)
Department of Medicine, Cardiology Division
Document Type