EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos).
Publication/Presentation Date
4-1-2016
Abstract
BACKGROUND AND AIMS: EUS-guided drainage of peripancreatic fluid collection (PFC) (pancreatic pseudocyst [PP] or walled-off necrosis [WON]) by using a novel lumen-apposing, fully covered, self-expandable metal stent (LAMS) has been promising, but few of these data are from the United States. The aim of this study was to evaluate clinical outcomes and safety of EUS-guided drainage of pancreatic pseudocysts and WON by using the LAMS.
METHODS: We conducted a multicenter, retrospective study on 82 patients with symptomatic PFC who underwent EUS-guided drainage by using the LAMS at 4 U.S. tertiary care centers. Outcomes evaluated included successful placement of the LAMS, the number of patients in whom complete resolution of PPs or WON was achieved, the number of procedures performed per patient to achieve PFC resolution, and adverse events.
RESULTS: The mean size of the PFC was 11.8 cm. LAMSs were successfully placed in 80 patients (97.5%). Twelve patients had PP and 68 had WON. The median stent in-dwelling time was 2 months (range 1-3 months). Endoscopic debridement with the LAMS in WON was performed in 54 patients. The patency of the stent was maintained in 98.7% of the patients (77/78). There was spontaneous dislodgment of 2 LAMSs. Successful endoscopic therapy by using the LAMS was successful in 12 of 12 patients (100%) with PP compared with 60 of 68 patients (88.2%) with WON. All stents were endoscopically removed from all patients after peripancreatic fluid collection (PFC) resolution. There was 1 PFC recurrence during the 3-month median follow-up period. Procedure-related adverse events occurred in 8 patients (9.8%), and included stent maldeployment (n = 2), and self-limited bleeding (n = 6). In 1 patient with stent maldeployment gastric perforation developed, and the patient underwent surgical repair.
CONCLUSION: EUS-guided drainage of PFCs by using the novel LAMS has high technical and long-term success rates. Due to its ease of use, the LAMSs may simplify and streamline EUS-guided management of PFCs, particularly for the endoscopic debridement of WON, and may help in its widespread adoption as an alternative to surgery.
Volume
83
Issue
4
First Page
699
Last Page
707
ISSN
1097-6779
Published In/Presented At
Siddiqui, A. A., Adler, D. G., Nieto, J., Shah, J. N., Binmoeller, K. F., Kane, S., Yan, L., Laique, S. N., Kowalski, T., Loren, D. E., Taylor, L. J., Munigala, S., & Bhat, Y. M. (2016). EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Gastrointestinal endoscopy, 83(4), 699–707. https://doi.org/10.1016/j.gie.2015.10.020
Disciplines
Medicine and Health Sciences
PubMedID
26515956
Department(s)
Department of Medicine
Document Type
Article