Effect of low-to-moderate hyperoxia on lung injury in preclinical animal models: a systematic review and meta-analysis.
Publication/Presentation Date
4-24-2023
Abstract
BACKGROUND: Extensive animal investigation informed clinical practice regarding the harmful effects of high fractional inspired oxygen concentrations (FiO
METHODS: Studies retrieved from systematic literature searches of three databases, that compared the effects of exposure to FiO
RESULTS: More than 600 retrieved reports investigated only FiO
INTERPRETATION: Limited animal studies have investigated FiO
Volume
11
Issue
1
First Page
22
Last Page
22
ISSN
2197-425X
Published In/Presented At
Minkove, S., Dhamapurkar, R., Cui, X., Li, Y., Sun, J., Cooper, D., Eichacker, P. Q., & Torabi-Parizi, P. (2023). Effect of low-to-moderate hyperoxia on lung injury in preclinical animal models: a systematic review and meta-analysis. Intensive care medicine experimental, 11(1), 22. https://doi.org/10.1186/s40635-023-00501-x
Disciplines
Medicine and Health Sciences
PubMedID
37088856
Department(s)
Department of Medicine
Document Type
Article