Ultrasound in the evaluation and management of the isoimmunized pregnancy.

Publication/Presentation Date

1-1-1981

Abstract

Real-time ultrasound was a valuable adjunct in the management of 57 consecutive isoimmunized pregnancies. The pathophysiology of hydrops fetalis as it affects the sonographic anatomy of the fetus and placenta is discussed. Real-time ultrasound was slightly more accurate than amniotic fluid bilirubin analysis in predicting moderate to severe erythroblastosis fetalis. The most useful finding was a disproportionate growth of the fetal abdominal circumference in relationship to the biparietal diameter. Ultrasound proved invaluable in several difficult situations, such as contaminated amniotic fluid, ruptured membranes, and twins. Suggestions for the further quantitation of this diagnostic test are explored.

Volume

9

Issue

6

First Page

315

Last Page

323

ISSN

0091-2751

PubMedID

6788813

Department(s)

Department of Obstetrics and Gynecology

Document Type

Article

Share

COinS