Modeling of non-small cell lung cancer volume changes during CT-based image guided radiotherapy: patterns observed and clinical implications.

Publication/Presentation Date

1-1-2013

Abstract

Background. To characterize the lung tumor volume response during conventional and hypofractionated radiotherapy (RT) based on diagnostic quality CT images prior to each treatment fraction. Methods. Out of 26 consecutive patients who had received CT-on-rails IGRT to the lung from 2004 to 2008, 18 were selected because they had lung lesions that could be easily distinguished. The time course of the tumor volume for each patient was individually analyzed using a computer program. Results. The model fits of group L (conventional fractionation) patients were very close to experimental data, with a median Δ% (average percent difference between data and fit) of 5.1% (range 3.5-10.2%). The fits obtained in group S (hypofractionation) patients were generally good, with a median Δ% of 7.2% (range 3.7-23.9%) for the best fitting model. Four types of tumor responses were observed-Type A: "high" kill and "slow" dying rate; Type B: "high" kill and "fast" dying rate; Type C: "low" kill and "slow" dying rate; and Type D: "low" kill and "fast" dying rate. Conclusions. The models used in this study performed well in fitting the available dataset. The models provided useful insights into the possible underlying mechanisms responsible for the RT tumor volume response.

Volume

2013

First Page

637181

Last Page

637181

ISSN

1748-6718

Disciplines

Medicine and Health Sciences | Oncology

PubMedID

24260040

Department(s)

Department of Radiation Oncology

Document Type

Article

Share

COinS