Performance Benchmarks for Screening Breast MR Imaging in Community Practice.
Publication/Presentation Date
10-1-2017
Abstract
Purpose To compare screening magnetic resonance (MR) imaging performance in the Breast Cancer Surveillance Consortium (BCSC) with Breast Imaging Reporting and Data System (BI-RADS) benchmarks. Materials and Methods This study was approved by the institutional review board and compliant with HIPAA and included BCSC screening MR examinations collected between 2005 and 2013 from 5343 women (8387 MR examinations) linked to regional Surveillance, Epidemiology, and End Results program registries, state tumor registries, and pathologic information databases that identified breast cancer cases and tumor characteristics. Clinical, demographic, and imaging characteristics were assessed. Performance measures were calculated according to BI-RADS fifth edition and included cancer detection rate (CDR), positive predictive value of biopsy recommendation (PPV
Volume
285
Issue
1
First Page
44
Last Page
52
ISSN
1527-1315
Published In/Presented At
Lee, J. M., Ichikawa, L., Valencia, E., Miglioretti, D. L., Wernli, K., Buist, D. S. M., Kerlikowske, K., Henderson, L. M., Sprague, B. L., Onega, T., Rauscher, G. H., & Lehman, C. D. (2017). Performance Benchmarks for Screening Breast MR Imaging in Community Practice. Radiology, 285(1), 44–52. https://doi.org/10.1148/radiol.2017162033
Disciplines
Diagnosis | Medicine and Health Sciences | Other Analytical, Diagnostic and Therapeutic Techniques and Equipment | Radiology
PubMedID
28582633
Department(s)
Department of Radiology and Diagnostic Medical Imaging
Document Type