Collaborative Development of a PACS-Integrated Quality Control Dashboard: a Single Institutional Experience.

Publication/Presentation Date

10-1-2022

Abstract

Regular communication between technologists and radiologists is necessary for maintaining optimal diagnostic image quality throughout a radiology practice. In a large hospital system with multiple sites, this task becomes increasingly difficult without simultaneously causing significant disruptions in the clinical workflow and decreased throughput. Thus, establishing a system for quality control reporting that enables effective communication in a seamless and convenient manner is imperative. In this report, we describe the development of a new integrated system, in collaboration with our PACS vendor, with tools that allow for instant reporting of quality errors and dashboards providing real-time up-to-date quality data across our hospital system, directly accessible from PACS. To date, 8,167 quality reports have been logged in our new system with roughly 355 submissions per month. Early user engagement and consensus feedback among radiologists and technologists have been positive suggesting an overall improvement from prior systems. We hope this report can help inform other radiology enterprises seeking to improve quality control reporting within their clinical practice.

Volume

35

Issue

5

First Page

1350

Last Page

1357

ISSN

1618-727X

Disciplines

Diagnosis | Medicine and Health Sciences | Other Analytical, Diagnostic and Therapeutic Techniques and Equipment | Radiology

PubMedID

35445342

Department(s)

Department of Radiology and Diagnostic Medical Imaging

Document Type

Article

Share

COinS