Comparing the Efficacy of True-Volume Analysis Using Magnetic Resonance Imaging With Computerized Tomography and Conventional Methods of Evaluation in Cystic Osteochondral Lesions of the Talus: A Pilot Study.

Publication/Presentation Date

12-1-2021

Abstract

UNLABELLED:

METHODS: With IRB approval, an institutional radiology database was queried for patients with cystic OLT that had undergone and failed microfracture and had compatible CT and MR scans between 2011 and 2016. Five lesions, previously analyzed and described in the literature using CT true-volume, were selected. 10 orthopedic surgeons independently estimated the volume of these 5 OLT via standard MRI. Next, 3D reconstructions were created and morphometric true-volume (MTV) analysis measurements of each OLT were generated. The percent change in volumes from CT and MR was compared based upon MTVs determined from 3D reconstructive analysis.

RESULTS: The volume calculated using conventional methods in CT and MR scans grossly overestimated the size by of the OLT by 285-864% and 56-374% respectively when compared to 3D true-volume analysis of those CT and MR scans.

CONCLUSIONS: This study demonstrates that true-volume is more accurate for calculating lesion size than conventional methods. Additionally, when comparing MRI and CT, thin slice CT true-volume is superior to MRI true-volume. True-volume calculation improves accuracy with CT and MRI and should be recommended for use in revision OLT cases.

Volume

14

Issue

6

First Page

501

Last Page

508

ISSN

1938-7636

Disciplines

Medicine and Health Sciences

PubMedID

32486861

Department(s)

Department of Surgery

Document Type

Article

Share

COinS