Factors affecting blood loss during percutaneous nephrolithotomy using balloon dilation in a large contemporary series.
Publication/Presentation Date
2-1-2010
Abstract
OBJECTIVE: Renal hemorrhage is a common and worrisome complication of percutaneous nephrolithotomy (PNL). We review factors affecting blood loss and transfusion requirements in a large contemporary series of patients undergoing PNL utilizing balloon dilation.
METHODS: We retrospectively reviewed all patients undergoing PNL at one institution from July 2000 to January 2008. Demographics, stone parameters, perioperative factors, complications, and stone-free rates were evaluated. Hemorrhage was estimated using hematocrit and blood transfusion requirement. Various factors were assessed for their association with blood loss using univariate models.
RESULTS: The 225 patients reviewed had a mean stone size of 3.5 +/- 1.8 cm (range, 0.6-9.0 cm), with 54 (23.4%) staghorn and 93 (40.3%) partial staghorn calculi. One hundred and seventy-five (75.8%), 173 (74.9%), and 80 (34.6%) had pelvic, lower pole, and upper pole calculi, respectively. Multiple access tracts were used in 12 (5.2%) patients, with overall stone-free and complication rates of 80.4% and 14.1%. Complications included postoperative fever in 15 patients (6.4%), clinically insignificant pleural effusion in 8 patients (3.4%), 2 (0.8%) renal artery pseudoaneurysms requiring angioembolization, and 1 (0.4%) urinoma requiring stent placement. Mean hematocrit decrease was 6.1 +/- 4.3%, with three (1.3%) patients receiving blood transfusions. On univariate analysis no other statistically significant differences were found between hematocrit decrease and stone size or location, presence of partial or complete staghorn calculi, diabetes, or number of access tracts.
CONCLUSIONS: We report a comparable stone-free rate and a lower incidence of blood transfusion among patients undergoing PNL using balloon dilation.
Volume
24
Issue
2
First Page
207
Last Page
211
ISSN
1557-900X
Published In/Presented At
Tomaszewski, J. J., Smaldone, M. C., Schuster, T., Jackman, S. V., & Averch, T. D. (2010). Factors affecting blood loss during percutaneous nephrolithotomy using balloon dilation in a large contemporary series. Journal of endourology, 24(2), 207–211. https://doi.org/10.1089/end.2009.0402
Disciplines
Medicine and Health Sciences
PubMedID
20039798
Department(s)
Department of Surgery
Document Type
Article