Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter.
Publication/Presentation Date
9-1-1994
Abstract
We describe a laparoscopic technique for relieving obstruction of a continuous ambulatory peritoneal dialysis (CAPD) catheter. Laparoscopic repositioning of the catheter and omentectomy obviated the need for laparotomy in a patient with end-stage renal disease.
Volume
8
Issue
9
First Page
1108
Last Page
1109
ISSN
0930-2794
Published In/Presented At
Hughes, C. R., Angotti, D. M., & Jubelirer, R. A. (1994). Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter. Surgical endoscopy, 8(9), 1108–1109. https://doi.org/10.1007/BF00705731