Conduction system pacing versus biventricular pacing: Reduced repolarization heterogeneity in addition to improved depolarization.

Publication/Presentation Date

2-1-2022

Abstract

INTRODUCTION: His-bundle pacing (HBP) and left-bundle-area pacing (LBAP) are conduction system pacing (CSP) modalities increasingly used as alternatives to conventional biventricular pacing (BiVP). While effects of CSP on ventricular depolarization have been reported, effects on ventricular repolarization have not.

METHODS: QRS duration (QRSd) and validated ECG parameters of ventricular repolarization associated with arrhythmic risk (T-peak-to-T-end

RESULTS: Although QRSd was shorter with HBP versus LBAP (119 ± 7 ms vs. 132 ± 9 ms, p = .02), there were no significant differences in any repolarization parameters between these methods of CSP. However, when comparing CSP (HBP + LBAP) to BiVP, both QRSd (125 ± 5 ms vs. 147 ± 7 ms, p <  .0001) and repolarization parameters (T-peak-to-T-end

CONCLUSIONS: In addition to improved depolarization, CSP reduced repolarization heterogeneity and provided greater T-wave memory resolution as compared to BiVP. Both modalities of CSP (HBP + LBAP) resulted in comparably reduced repolarization heterogeneity regardless of baseline QRSd and LV function. These observations may confer lower arrhythmogenic risk and warrant further study.