The development of two Point of Care Ultrasound stations for Objective Structured Clinical Examinations in undergraduate medical education.

Publication/Presentation Date

4-1-2026

Abstract

INTRODUCTION: Point-of-care ultrasound (POCUS) is a valuable clinical skill that improves clinical care but requires substantial training. Validated assessment tools provide empirical evidence regarding trainee performance while also informing program-level evaluation. We developed two POCUS-specific stations for objective structured clinical examinations (OSCEs) to assess skill acquisition and inform best practices in undergraduate medical education.

METHODS: A multidisciplinary group of POCUS educators identified two POCUS applications (pleural effusion and abdominal free fluid) well suited for the undergraduate level. A modified Delphi approach was used to develop POCUS-application-specific skill checklists and global rating scale. Two medical programs piloted the stations to inform reliability.

RESULTS: Across two sites, 46 and 41 students participated in the pleural effusion and abdominal free fluid stations respectively. Checklists showed high internal reliability, with Cronbach's alpha of 0.85 (95% CI 0.71-0.93) for the pleural effusion station and 0.87 (95% CI 0.74-0.95) for the abdominal free fluid station. Krippendorff's alpha, a measure of inter-rater reliability, was also equally strong at 0.85 (95% CI 0.43-0.94) and 0.83 (95% CI 0.50-0.94) respectively.

CONCLUSION: Both POCUS OSCE stations demonstrated good internal and inter-rater reliability. Deployment of these OSCE stations at programs with integrated POCUS curricula may help refine programming and training expectations.

Volume

17

Issue

2

First Page

62

Last Page

70

ISSN

1923-1202

Disciplines

Business Administration, Management, and Operations | Health and Medical Administration | Management Sciences and Quantitative Methods

PubMedID

42254949

Department(s)

Administration and Leadership

Document Type

Article

Share