Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure.

Publication/Presentation Date

1-1-2020

Abstract

BACKGROUND: Accurately assessing volume status in acutely decompensated heart failure (ADHF) can be challenging. Inferior vena cava (IVC) dynamics by echocardiography allow indirect assessment of volume status in these patients. Recently introduced hand-held ultrasound devices are promising. We aimed to describe the clinical correlates of volume status assessment using a hand-held ultrasound device in ADHF.

METHODS: In this prospective study, we evaluated 106 patients admitted with ADHF. First scan was performed within 24 hours of admission and timed in reference to first dose of intravenous diuretic. Daily resting and inspiratory (sniff) IVC diameters were measured according to standard echocardiography methods during hospitalization including the day of discharge. IVC collapsibility index (IVC-CI = Maximum IVC diameter-Inspiratory IVC diameter/maximum diameter;

RESULTS: Data for 106 patients was analyzed. Mean age was 66.7 ± 13.8 years, of which 53.8% were females, and a mean ejection fraction was 39 ± 18%. Initial scan of the IVC was obtained at an average time of 5.2 ± 8.04 hours from first diuretic dose. 81.2% of patients at admission had an IVC-CI

CONCLUSION: Hand-held ultrasound assessment of IVC-CI in ADHF patients, although a feasible concept, is unable to predict 30-day readmissions in our study. Further prospective studies are necessary.

Volume

37

Issue

1

First Page

22

Last Page

28

ISSN

1540-8175

Disciplines

Medicine and Health Sciences

PubMedID

31786825

Department(s)

Fellows and Residents

Document Type

Article

Share

COinS