Re-implantation of suboptimal prostate seed implantation: technique with intraoperative treatment planning.
Publication/Presentation Date
9-1-2012
Abstract
PURPOSE: Post-implant dosimetry following prostate seed implantation (PSI) occasionally reveals suboptimal dosimetric coverage of the gland. Published reports of re-implantation techniques have focused on earlier-generation techniques, including preplanned approaches and stranded seeds. The purpose of this case report is to describe a customizable approach to perform corrective re-implantation using loose seeds and intraoperative planning technique.
MATERIAL AND METHODS: This case report describes a 63-year-old male with favorable risk prostate adenocarcinoma receiving PSI. Thirty day post-implant dosimetric evaluation revealed suboptimal coverage of the base of the gland. Using guidance from post-implant CT-images and real-time planning, the patient received a corrective re-implantation with intraoperative planning.
RESULTS: Post-implant dosimetry after re-implantation procedure with intraoperative planning yielded improved target volume coverage that achieved standard dosimetric criteria.
CONCLUSIONS: Re-implantation as a salvage treatment technique after sub-optimal PSI is a valid treatment option performed with intraoperative real-time planning.
Volume
4
Issue
3
First Page
176
Last Page
181
ISSN
1689-832X
Published In/Presented At
Doyle, L., Hesney, A. J., Chapman, K. L., Liu, H., Weiner, P. R., Dicker, A. P., Yu, Y., & Showalter, T. N. (2012). Re-implantation of suboptimal prostate seed implantation: technique with intraoperative treatment planning. Journal of contemporary brachytherapy, 4(3), 176–181. https://doi.org/10.5114/jcb.2012.30684
Disciplines
Medicine and Health Sciences
PubMedID
23346147
Department(s)
Fellows and Residents
Document Type
Article