Detection of group D and viridans streptococci in blood by radiometric methods.

Authors

D G Beckwith

Publication/Presentation Date

1-1-1979

Abstract

A prospective study was conducted to evaluate the radiometric detection of group D and viridans streptococci in blood, using three media preparations, Bactec 6A and 6B isotonic media and 8B hypertonic medium. All enterococci tested were detected by the 6A and 6B media. However, the 6A medium failed to detect 76% of the Streptococcus bovis isolates and 57% of the viridans streptococci, whereas all S. bovis isolates and 95% of the viridans streptococci were detected with the 6B formulation. No improvement in detection was noted in comparing the 6B and the 8B hypertonic media. The importance of adequate detection of this group of organisms, especially in patients with endocarditis, is discussed.

Volume

9

Issue

1

First Page

20

Last Page

22

ISSN

0095-1137

Disciplines

Medicine and Health Sciences

PubMedID

429537